- PAGE DE TITRE (Première image)
- Préface (p.1)
- Liste des exposants (p.5)
- Index (p.7)
- 1. Surveying and calculating apparatus (p.7)
- Theodolites, levels, prismatic and mining compasses, aneroids : Negretti and Zambra (p.143)
- Theodolites, levels, prismatic and mining compasses, aneroids : Pillischer (p.178)
- Theodolites, levels, prismatic and mining compasses, aneroids : Stanley (p.181)
- Theodolites, levels, prismatic and mining compasses, aneroids : Steward (p.199)
- Theodolites, levels, prismatic and mining compasses, aneroids : Steward (p.204)
- Nautical sextants : Negretti and Zambra (p.144)
- Nautical sextants : Stanley (p.195)
- Nautical sextants : Steward (p.201)
- Drawing Instruments : Brooks (p.1)
- Drawing Instruments : Negretti and Zambra (p.144)
- Miscellaneous : Range-finder. Steward (p.203)
- Miscellaneous : Fuller's slide rule. Stanley (p.197)
- Miscellaneous : Heliograph. Steward (p.207)
- Miscellaneous : Helio-chronometer. Negretti and Zambra (p.146)
- Miscellaneous : Clocks, electrical. Synchronome Co (p.226)
- 2. Navigational Instruments (p.7)
- 3. Meteorological Instruments (p.7)
- Thermometers, barometers, sunshine recorders, rain gauges, anemometers : Darton (p.59)
- Thermometers, barometers, sunshine recorders, rain gauges, anemometers : Negretti and Zambra (p.130)
- Thermometers, barometers, sunshine recorders, rain gauges, anemometers : Pillischer (p.177)
- Thermometers, barometers, sunshine recorders, rain gauges, anemometers : Steward (p.204)
- Deep sea thermometers. Negretti and Zambra (p.138)
- Industrial thermometers. Camb. Sci. Instr. Co (p.37)
- Meldometer. Camb. Sci. Instr. Co (p.45)
- Clinical thermometers : Negretti and Zambra (p.143)
- Clinical thermometers : Pillischer (p.177)
- Temperature regulator. Camb. Sci. Instr. Co (p.39)
- 4. Mechanical Apparatus (p.8)
- Models. Cussons (p.54)
- Balancing of machines. Cussons (p.57)
- Impact testing. Camb. Sci. Instr. Co (p.43)
- Cup micrometer. Camb. Sci. Instr. Co (p.52)
- Extensometers Camb. Sci. Instr. Co (p.48)
- Extensometers Camb. Sci. Instr. Co (p.51)
- Comparator Camb. Sci. Instr. Co (p.50)
- Cathetometer Camb. Sci. Instr. Co (p.51)
- Chronograph Camb. Sci. Instr. Co (p.49)
- Laboratory stands Camb. Sci. Instr. Co (p.52)
- Joule apparatus Camb. Sci. Instr. Co (p.47)
- Temperature regulator Camb. Sci. Instr. Co (p.39)
- Coal Calorimeter. Cussons (p.57)
- 5. Optical Instruments (p.8)
- Spectroscopes, spectrometers, refractometers : Hilger (p.83)
- Spectroscopes, spectrometers, refractometers : Steward (p.208)
- Microscopes, objectives, eye-pieces : Negretti and Zambra (p.146)
- Microscopes, objectives, eye-pieces : Pillischer (p.178)
- Microscopes, objectives, eye-pieces : Swift (p.210)
- Goniometers. Swift (p.215)
- Lamps. Swift (p.225)
- Microtomes and accessories. Camb. Sci. Instr. Co (p.40)
- Telescopes and field glasses : Negretti and Zambra (p.145)
- Telescopes and field glasses : Pillischer (p.178)
- Telescopes and field glasses : Steward (p.198)
- Mirrors : Gowlland (p.79)
- Mirrors : Reflector Co (p.179)
- Lantern apparatus : Cussons (p.55)
- Lantern apparatus : Nalder (p.71)
- Oculists' apparatus : Dunscombe (p.62)
- Oculists' apparatus : Gowlland (p.72)
- Oculists' apparatus : Pillischer (p.178)
- 6. Electrical Apparatus (p.8)
- Weston normal cells : Camb. Sci. Instr. Co (p.23)
- Weston normal cells : Paul (p.161)
- Standard resistances : Camb. Sci. Instr. Co (p.24)
- Standard resistances : Paul (p.155)
- Resistance Boxes : Camb. Sci. Instr. Co (p.32)
- Resistance Boxes : Gambrell (p.67)
- Resistance Boxes : Paul (p.156)
- Resistance Boxes : Paul (p.174)
- Potentiometer : Camb. Sci. Instr. Co (p.27)
- Apparatus for induction measurements : Camb. Sci. Instr. Co (p.22)
- Apparatus for induction measurements : Paul (p.167)
- Apparatus for induction measurements : Paul (p.171)
- Test wires : Gambrell (p.68)
- Test wires : Paul (p.157)
- Condensers : Paul (p.161)
- Moving coil instruments : Camb. Sci. Instr. Co (p.15)
- Moving coil instruments : Gambrell (p.63)
- Moving coil instruments : Gambrell (p.70)
- Moving coil instruments : Paul (p.147)
- Moving coil instruments : Paul (p.159)
- Special galvanometers : Einthoven. Camb. Sci. Instr. Co (p.9)
- Special galvanometers : Broca. Camb. Sci. Instr. Co (p.13)
- Special galvanometers : Twisted strip. Camb. Sci. Instr. Co (p.16)
- Special galvanometers : String. Camb. Sci. Instr. Co (p.17)
- Special galvanometers : Duddell thermo. Camb. Sci. Instr. Co (p.20)
- Special galvanometers : Unipivot. Paul (p.147)
- Special galvanometers : Sumpner. Paul (p.166)
- Special galvanometers : Cohen. Paul (p.168)
- Special galvanometers : Campbell. Paul (p.173)
- Galvanometer shunts : Gambrell (p.66)
- Galvanometer shunts : Paul (p.161)
- Ammeters and Voltmeters. Portable Instruments : Kelvin and White (p.110)
- Ammeters and Voltmeters. Portable Instruments : Nalder (p.119)
- Ammeters and Voltmeters. Portable Instruments : Paul (p.151)
- Switch Board Instruments : Kelvin and White (p.103)
- Switch Board Instruments : Nalder (p.115)
- Switch Board Instruments : Nalder (p.123)
- Recording Instruments : Camb. Sci. Instr. Co (p.26)
- Recording Instruments : Camb. Sci. Instr. Co (p.31)
- Recording Instruments : Kelvin and White (p.104)
- Recording Instruments : Nalder (p.121)
- Shunts for Ammeters : Paul (p.150)
- Electrostatic voltmeters : Dolezalek. Camb. Sci. Instr. Co (p.18)
- Electrostatic voltmeters : Electroscope (p.19)
- Electrostatic voltmeters : Ayrton-Mather. Paul (p.164)
- Electrostatic voltmeters : Kelvin. Kelvin and White (p.106)
- Wattmeters : Kelvin. Kelvin and White (p.105)
- Wattmeters : Unipivot. Paul (p.153)
- Wattmeters : Duddell Mather. Paul (p.162)
- Wattmeters : Drysdale. Nalder (p.117)
- Insulation testing apparatus : Kelvin and White (p.106)
- Insulation testing apparatus : Nalder (p.125)
- Insulation testing apparatus : Paul (p.151)
- Oscillographs : Duddell. Camb. Sci. Instr. Co (p.6)
- Oscillographs : Irwin. Paul (p.169)
- Regulating resistances : Paul (p.158)
- Switches : Laboratory Gambrell (p.68)
- Switches : Laboratory Paul (p.175)
- Switches : Battery. Nalder (p.124)
- Switches : Circuit breaker. Nalder (p.128)
- Switches : Current limiter. Nalder (p.129)
- Electrical methods of temperature measurement : Camb. Sci. Instr. Co (p.25)
- Electrical methods of temperature measurement : Camb. Sci. Instr. Co (p.45)
- Electrical methods of temperature measurement : Nalder (p.126)
- Electrical methods of temperature measurement : Paul (p.153)
- Carbon brushes for machines : Morgan Crucible Co (p.111)
- Lightning arrester : Morgan Crucible Co (p.113)
- Electric clocks : Synchronome Co (p.226)
- Dernière image
6 OR
bridge methods. It is direct reading with ranges - 200° to O°, 0° to 200°, 200° to 400°, &c., up to 1,200°, on the one instrument.
A deflection of 90 angular degrees is produced by 200° of temperature with a platinum thermometer of 1 ohm fundamental interval. The accuracy can be easily checked by immersing the thermometer in ice and steam. At the National Physical Laboratory the error up the 1,200° has been found not to exceed 1000: The instrument can be calibrated in platinum degrees for use with any make of platinum thermometers.
Platinum Resistance Thermometers.
The platinum is in the form of flat strip to minimise the effect of heating by the measuring- current. The mounting depends on the temperature to be measured. They are made of 1 ohm "fundamental interval,” that is the change in resistance from 0° to 100° C. is 1 ohm. The total resistance at 0° is made 3 ohms by the addition of a, small resistance without temperature co-efficient. In this way all thermometers are interchangeable for use with the Direct Reading Indicator or any other piece of apparatus. Compensating leads are provided in the usual way.
Drysdale Standard Resistance Coil, 1 ohm. (Fig. 13.)
FIG. 13.
Le texte affiché peut comporter un certain nombre d'erreurs. En effet, le mode texte de ce document a été généré de façon automatique par un programme de reconnaissance optique de caractères (OCR). Le taux de reconnaissance estimé pour cette page est de 98,75 %.
La langue de reconnaissance de l'OCR est l'Anglais.
bridge methods. It is direct reading with ranges - 200° to O°, 0° to 200°, 200° to 400°, &c., up to 1,200°, on the one instrument.
A deflection of 90 angular degrees is produced by 200° of temperature with a platinum thermometer of 1 ohm fundamental interval. The accuracy can be easily checked by immersing the thermometer in ice and steam. At the National Physical Laboratory the error up the 1,200° has been found not to exceed 1000: The instrument can be calibrated in platinum degrees for use with any make of platinum thermometers.
Platinum Resistance Thermometers.
The platinum is in the form of flat strip to minimise the effect of heating by the measuring- current. The mounting depends on the temperature to be measured. They are made of 1 ohm "fundamental interval,” that is the change in resistance from 0° to 100° C. is 1 ohm. The total resistance at 0° is made 3 ohms by the addition of a, small resistance without temperature co-efficient. In this way all thermometers are interchangeable for use with the Direct Reading Indicator or any other piece of apparatus. Compensating leads are provided in the usual way.
Drysdale Standard Resistance Coil, 1 ohm. (Fig. 13.)
FIG. 13.
Le texte affiché peut comporter un certain nombre d'erreurs. En effet, le mode texte de ce document a été généré de façon automatique par un programme de reconnaissance optique de caractères (OCR). Le taux de reconnaissance estimé pour cette page est de 98,75 %.
La langue de reconnaissance de l'OCR est l'Anglais.



