- PAGE DE TITRE (Première image)
- Préface (p.1)
- Liste des exposants (p.5)
- Index (p.7)
- 1. Surveying and calculating apparatus (p.7)
- Theodolites, levels, prismatic and mining compasses, aneroids : Negretti and Zambra (p.143)
- Theodolites, levels, prismatic and mining compasses, aneroids : Pillischer (p.178)
- Theodolites, levels, prismatic and mining compasses, aneroids : Stanley (p.181)
- Theodolites, levels, prismatic and mining compasses, aneroids : Steward (p.199)
- Theodolites, levels, prismatic and mining compasses, aneroids : Steward (p.204)
- Nautical sextants : Negretti and Zambra (p.144)
- Nautical sextants : Stanley (p.195)
- Nautical sextants : Steward (p.201)
- Drawing Instruments : Brooks (p.1)
- Drawing Instruments : Negretti and Zambra (p.144)
- Miscellaneous : Range-finder. Steward (p.203)
- Miscellaneous : Fuller's slide rule. Stanley (p.197)
- Miscellaneous : Heliograph. Steward (p.207)
- Miscellaneous : Helio-chronometer. Negretti and Zambra (p.146)
- Miscellaneous : Clocks, electrical. Synchronome Co (p.226)
- 2. Navigational Instruments (p.7)
- 3. Meteorological Instruments (p.7)
- Thermometers, barometers, sunshine recorders, rain gauges, anemometers : Darton (p.59)
- Thermometers, barometers, sunshine recorders, rain gauges, anemometers : Negretti and Zambra (p.130)
- Thermometers, barometers, sunshine recorders, rain gauges, anemometers : Pillischer (p.177)
- Thermometers, barometers, sunshine recorders, rain gauges, anemometers : Steward (p.204)
- Deep sea thermometers. Negretti and Zambra (p.138)
- Industrial thermometers. Camb. Sci. Instr. Co (p.37)
- Meldometer. Camb. Sci. Instr. Co (p.45)
- Clinical thermometers : Negretti and Zambra (p.143)
- Clinical thermometers : Pillischer (p.177)
- Temperature regulator. Camb. Sci. Instr. Co (p.39)
- 4. Mechanical Apparatus (p.8)
- Models. Cussons (p.54)
- Balancing of machines. Cussons (p.57)
- Impact testing. Camb. Sci. Instr. Co (p.43)
- Cup micrometer. Camb. Sci. Instr. Co (p.52)
- Extensometers Camb. Sci. Instr. Co (p.48)
- Extensometers Camb. Sci. Instr. Co (p.51)
- Comparator Camb. Sci. Instr. Co (p.50)
- Cathetometer Camb. Sci. Instr. Co (p.51)
- Chronograph Camb. Sci. Instr. Co (p.49)
- Laboratory stands Camb. Sci. Instr. Co (p.52)
- Joule apparatus Camb. Sci. Instr. Co (p.47)
- Temperature regulator Camb. Sci. Instr. Co (p.39)
- Coal Calorimeter. Cussons (p.57)
- 5. Optical Instruments (p.8)
- Spectroscopes, spectrometers, refractometers : Hilger (p.83)
- Spectroscopes, spectrometers, refractometers : Steward (p.208)
- Microscopes, objectives, eye-pieces : Negretti and Zambra (p.146)
- Microscopes, objectives, eye-pieces : Pillischer (p.178)
- Microscopes, objectives, eye-pieces : Swift (p.210)
- Goniometers. Swift (p.215)
- Lamps. Swift (p.225)
- Microtomes and accessories. Camb. Sci. Instr. Co (p.40)
- Telescopes and field glasses : Negretti and Zambra (p.145)
- Telescopes and field glasses : Pillischer (p.178)
- Telescopes and field glasses : Steward (p.198)
- Mirrors : Gowlland (p.79)
- Mirrors : Reflector Co (p.179)
- Lantern apparatus : Cussons (p.55)
- Lantern apparatus : Nalder (p.71)
- Oculists' apparatus : Dunscombe (p.62)
- Oculists' apparatus : Gowlland (p.72)
- Oculists' apparatus : Pillischer (p.178)
- 6. Electrical Apparatus (p.8)
- Weston normal cells : Camb. Sci. Instr. Co (p.23)
- Weston normal cells : Paul (p.161)
- Standard resistances : Camb. Sci. Instr. Co (p.24)
- Standard resistances : Paul (p.155)
- Resistance Boxes : Camb. Sci. Instr. Co (p.32)
- Resistance Boxes : Gambrell (p.67)
- Resistance Boxes : Paul (p.156)
- Resistance Boxes : Paul (p.174)
- Potentiometer : Camb. Sci. Instr. Co (p.27)
- Apparatus for induction measurements : Camb. Sci. Instr. Co (p.22)
- Apparatus for induction measurements : Paul (p.167)
- Apparatus for induction measurements : Paul (p.171)
- Test wires : Gambrell (p.68)
- Test wires : Paul (p.157)
- Condensers : Paul (p.161)
- Moving coil instruments : Camb. Sci. Instr. Co (p.15)
- Moving coil instruments : Gambrell (p.63)
- Moving coil instruments : Gambrell (p.70)
- Moving coil instruments : Paul (p.147)
- Moving coil instruments : Paul (p.159)
- Special galvanometers : Einthoven. Camb. Sci. Instr. Co (p.9)
- Special galvanometers : Broca. Camb. Sci. Instr. Co (p.13)
- Special galvanometers : Twisted strip. Camb. Sci. Instr. Co (p.16)
- Special galvanometers : String. Camb. Sci. Instr. Co (p.17)
- Special galvanometers : Duddell thermo. Camb. Sci. Instr. Co (p.20)
- Special galvanometers : Unipivot. Paul (p.147)
- Special galvanometers : Sumpner. Paul (p.166)
- Special galvanometers : Cohen. Paul (p.168)
- Special galvanometers : Campbell. Paul (p.173)
- Galvanometer shunts : Gambrell (p.66)
- Galvanometer shunts : Paul (p.161)
- Ammeters and Voltmeters. Portable Instruments : Kelvin and White (p.110)
- Ammeters and Voltmeters. Portable Instruments : Nalder (p.119)
- Ammeters and Voltmeters. Portable Instruments : Paul (p.151)
- Switch Board Instruments : Kelvin and White (p.103)
- Switch Board Instruments : Nalder (p.115)
- Switch Board Instruments : Nalder (p.123)
- Recording Instruments : Camb. Sci. Instr. Co (p.26)
- Recording Instruments : Camb. Sci. Instr. Co (p.31)
- Recording Instruments : Kelvin and White (p.104)
- Recording Instruments : Nalder (p.121)
- Shunts for Ammeters : Paul (p.150)
- Electrostatic voltmeters : Dolezalek. Camb. Sci. Instr. Co (p.18)
- Electrostatic voltmeters : Electroscope (p.19)
- Electrostatic voltmeters : Ayrton-Mather. Paul (p.164)
- Electrostatic voltmeters : Kelvin. Kelvin and White (p.106)
- Wattmeters : Kelvin. Kelvin and White (p.105)
- Wattmeters : Unipivot. Paul (p.153)
- Wattmeters : Duddell Mather. Paul (p.162)
- Wattmeters : Drysdale. Nalder (p.117)
- Insulation testing apparatus : Kelvin and White (p.106)
- Insulation testing apparatus : Nalder (p.125)
- Insulation testing apparatus : Paul (p.151)
- Oscillographs : Duddell. Camb. Sci. Instr. Co (p.6)
- Oscillographs : Irwin. Paul (p.169)
- Regulating resistances : Paul (p.158)
- Switches : Laboratory Gambrell (p.68)
- Switches : Laboratory Paul (p.175)
- Switches : Battery. Nalder (p.124)
- Switches : Circuit breaker. Nalder (p.128)
- Switches : Current limiter. Nalder (p.129)
- Electrical methods of temperature measurement : Camb. Sci. Instr. Co (p.25)
- Electrical methods of temperature measurement : Camb. Sci. Instr. Co (p.45)
- Electrical methods of temperature measurement : Nalder (p.126)
- Electrical methods of temperature measurement : Paul (p.153)
- Carbon brushes for machines : Morgan Crucible Co (p.111)
- Lightning arrester : Morgan Crucible Co (p.113)
- Electric clocks : Synchronome Co (p.226)
- Dernière image
167
voltage coil be used, the voltage for the condenser circuit may be transformed up by using the line wire coils to supply it.
For example — Capacity, mfds. Volts, for 10 mm.
Volts on C - Condenser on AB - 5 0’005
C - C - 2’5 0’031
AB - AB - 1 0’22
AB - C - 0’1 31
The sensitivity may be increased by connecting the magnet coils to a separate source of supply at 100 or 200 volts. By this means less than one micro-volt may be detected.
The application of the instrument to the measurement of large and small capacities down to 0’00005 mfd. will be understood from the above. It may be used for such purposes as determining the effective resistance of a conductor placed in series with a similar resistance of known properties.
By means of series quadrature transformers it may be used as a wattmeter,, and it will measure very small powers when used in this manner.
Cohens Interrupter. (Fig. 29.)
(“ Phil. Mag,” Sept. 1908.)
Fig. 29.
Le texte affiché peut comporter un certain nombre d'erreurs. En effet, le mode texte de ce document a été généré de façon automatique par un programme de reconnaissance optique de caractères (OCR). Le taux de reconnaissance estimé pour cette page est de 99,04 %.
La langue de reconnaissance de l'OCR est l'Anglais.
voltage coil be used, the voltage for the condenser circuit may be transformed up by using the line wire coils to supply it.
For example — Capacity, mfds. Volts, for 10 mm.
Volts on C - Condenser on AB - 5 0’005
C - C - 2’5 0’031
AB - AB - 1 0’22
AB - C - 0’1 31
The sensitivity may be increased by connecting the magnet coils to a separate source of supply at 100 or 200 volts. By this means less than one micro-volt may be detected.
The application of the instrument to the measurement of large and small capacities down to 0’00005 mfd. will be understood from the above. It may be used for such purposes as determining the effective resistance of a conductor placed in series with a similar resistance of known properties.
By means of series quadrature transformers it may be used as a wattmeter,, and it will measure very small powers when used in this manner.
Cohens Interrupter. (Fig. 29.)
(“ Phil. Mag,” Sept. 1908.)
Fig. 29.
Le texte affiché peut comporter un certain nombre d'erreurs. En effet, le mode texte de ce document a été généré de façon automatique par un programme de reconnaissance optique de caractères (OCR). Le taux de reconnaissance estimé pour cette page est de 99,04 %.
La langue de reconnaissance de l'OCR est l'Anglais.



