- Contents (p.3)
- Illuminating Appliances and Condensers (p.4)
- Artificial Sources of Light for use with the microscope (p.16)
- Objective Changers (p.22)
- Mechanical Stages and Warm Stages (p.24)
- Micrometers (p.33)
- Drawing and Demonstrating Appliances (p.36)
- Polarising Attachments (p.43)
- Microscopic Adjuncts (p.45)
- Dissecting and Mounting Sets (p.46)
- Index (* Signifies that the apparatus is illustrated) (p.47)
- Abbe drawing apparatus * (p.38)
- Analyser * (p.43)
- Aplanatic Condenser * (p.9)
- Apparatus for drawing and demonstrating projected images * (p.39)
- Apparatus for drawing objects in their natural size * (p.40)
- Arc Lamp, Liliput * (p.19)
- Bell Jar (p.46)
- Botanical dissecting case (p.46)
- Bull's Eye condenser * (p.21)
- Capped Bottle (p.45)
- Carbons (p.21)
- Cases (p.46)
- Cedarwood Oil (p.45)
- Centre Stop (p.10)
- Centre stop iris diaphragm (p.10)
- Clockwork-regulated Liliput arc lamp * (p.20)
- Clutch changers * (p.23)
- Compressor * (p.32)
- Condensers * (p.4)
- Condensers for dark ground illumination * (p.12)
- Conical stop * (p.12)
- Cover-glass gauge (p.45)
- Contents (p.3)
- Cover-glasses (p.45)
- Cross-line Micrometer (p.34)
- Cylinder iris-diaphragm * (p.10)
- Dark-ground illuminators * (p.13)
- Demonstrating eyepiece * (p.41)
- Dissecting and mounting cases (p.46)
- Double demonstrating eyepiece * (p.42)
- Drawing apparatus * (p.38)
- Drawing eyepieces * (p.38)
- Drawing stands * (p.38)
- Echelon micrometer * (p.34)
- Electrically heated stage * (p.29)
- Engraving (p.46)
- Electrical object stage * (p.31)
- Erecting prism (p.43)
- Eyepiece Micrometers * (p.34)
- Giesenhagen's drawing board * (p.38)
- Ground glass disc on stand (p.21)
- Glass micrometer (p.34)
- Illuminating apparatus * (p.4)
- Illuminating lens * (p.21)
- Iris diaphragm (p.10)
- Ivory Glow-lamp (p.21)
- Kaatzer's sputum set (p.46)
- Kuzitzky's pointer eyepiece * (p.41)
- Leather Cases (p.46)
- Liliput Arc Lamp * (p.19)
- Loose Collars * (p.23)
- Luminescence Lamp * (p.17)
- Meat Inspector's Outfit (p.46)
- Mechanical stages * (p.24)
- Mercury thermometers (p.31)
- Micrometers (p.33)
- Micrometer eyepieces (p.33)
- Nosepieces * (p.22)
- Objective changers * (p.23)
- Objective clutch changers * (p.23)
- Objective shield * (p.30)
- Object Marker * (p.41)
- Object Slides (p.45)
- Pfeiffer's warm stage * (p.28)
- Pointer eyepiece * (p.41)
- Polariser * (p.43)
- Prism erecting (p.43)
- Reflecting condensers * (p.13)
- Requisites (p.46)
- Resistances- electrical (p.21)
- Revolving nosepieces * (p.22)
- Schultze's warm stage * (p.28)
- Screw micrometer * (p.33)
- Selenite and mica films (p.44)
- Selenite slider (p.44)
- Slides (p.45)
- Stage, electrical * (p.29)
- Stage screw micrometer (p.33)
- Sputum case (p.46)
- Stage micrometer (p.35)
- Strickers's warm stage * (p.28)
- Substage illuminating apparatus (p.4)
- Swing-out condensers (p.4)
- Thermometer (p.31)
- Turntable * (p.45)
- Ultra condenser * (p.15)
- Ultra-microscope arrangement * (p.15)
- Vertical illuminator * (p.10)
- Warm stages * (p.28)
- Wooden base with Liliput Lamp * (p.20)
- Ziegler's compressor * (p.32)
- Contents (p.3)
- Dernière image
fe s. d. Codeword
No.
167. Drawing Board. When set up this board provides a
drawing surface inclined at 12°. which in the case of the Drawing Eyepiece No. .163 obviates the appearance of any distortion .......................................0. 5. 0 Desinatum
168. Giesenhagen’s Drawing Board is adjustable and may be fixed at various angles of slope as well as raised
and lowered..............................................0.10. 0 Desinavero
In the case of Drawing Eyepiece No. 164 and the Abbe Drawing Camera the drawing boards should be horizontal.
Apparatus for Drawing and Demonstrating Projected Images No. 172.
Apparatus for Drawing and Demonstrating Projected Images.
At the suggestion of Prof. Edinger we have devised a Drawing Mirror Attachment which may be affixed to any inclinable microscope and clamped in any required position above the eyepiece.
The illumination of the object, which naturally requires to be very intense, is best supplied by means of a Liliput Lamp, The drawing surface lies behind the microscope and is screened off from adventitious light by a tent arrangement of black cloth. The mirror,
39
Le texte affiché peut comporter un certain nombre d'erreurs. En effet, le mode texte de ce document a été généré de façon automatique par un programme de reconnaissance optique de caractères (OCR). Le taux de reconnaissance estimé pour cette page est de 99,43 %.
La langue de reconnaissance de l'OCR est l'Anglais.
No.
167. Drawing Board. When set up this board provides a
drawing surface inclined at 12°. which in the case of the Drawing Eyepiece No. .163 obviates the appearance of any distortion .......................................0. 5. 0 Desinatum
168. Giesenhagen’s Drawing Board is adjustable and may be fixed at various angles of slope as well as raised
and lowered..............................................0.10. 0 Desinavero
In the case of Drawing Eyepiece No. 164 and the Abbe Drawing Camera the drawing boards should be horizontal.
Apparatus for Drawing and Demonstrating Projected Images No. 172.
Apparatus for Drawing and Demonstrating Projected Images.
At the suggestion of Prof. Edinger we have devised a Drawing Mirror Attachment which may be affixed to any inclinable microscope and clamped in any required position above the eyepiece.
The illumination of the object, which naturally requires to be very intense, is best supplied by means of a Liliput Lamp, The drawing surface lies behind the microscope and is screened off from adventitious light by a tent arrangement of black cloth. The mirror,
39